• [email protected]
  • (519) 250-2058
  • 2090 Fasan Dr, Oldcastle, ON N0R 1L0

Follow Us

Facebook Instagram Youtube X-twitter Linkedin
Official logo of True Phantom Solutions
  • Home
  • About
  • Radiographs
    • X-Ray Scans
    • Ultrasound Scans
    • CT Scans
    • MRI Scans
  • Publications & News
    • Publications
    • News
  • Contact
  • Home
  • About
  • Radiographs
    • X-Ray Scans
    • Ultrasound Scans
    • CT Scans
    • MRI Scans
  • Publications & News
    • Publications
    • News
  • Contact
Quotes
Official logo of True Phantom Solutions
  • All Products
  • X-Ray CT, US, MRI
    Adults
    • Head (Dynamic, Advanced)
    • Head (Standard)
    • Female Heart
    • Heart
    • Brain (Complex)
    • Skull
    • View All
    Pediatric
    • Newborn Skull
    • Newborn Head (Dynamic)
    Geometrical
    • Cylindrical Head
    • Cylindrical Skull
    • Planar Skull Bone Phantoms
    • Doppler Phantom
  • X-Ray CT, US
    Adults
    • Torso (Skin)
    • Full Body (with Muscles)
    • Full Body
    • Torso
    • Torso (Dynamic)
    • Torso (Cardiac/FAST)
    • Knee (Extended)
    • Sectional Abdomen
    • Pelvis with Organs
    • Female Torso (Dynamic)
    • Female Torso
    Pediatric
    • Pediatric Full Body
    • Newborn Torso
    • Newborn Torso (Advanced)
    • Newborn Torso (Transparent)
    Veterinary
    • Rat Phantom (Anatomical)
    Geometrical
    • Rat Phantom (Cylindrical)
  • X-Ray CT, MRI
    Adults
    • Full Body (with Muscles)
    • Full Body
    • Male Torso
    • Male Torso (Dynamic)
    • Torso (Cardiac)
    • Female Torso
    • Female Torso (Dynamic)
    • Pelvis with Organs
    Pediatric
    • Full Body
    • Newborn Torso (Advanced
    Veterinary
    • Rat Phantom (Anatomical)
    Geometrical
    • Rat Phantom (Cylindrical)
  • X-Ray CT
    Adults
    • Full Body
    • Adult Spine
    • Adult Dental Skull
    Veterinary
    • Sectional Rat
    • Sectional Mouse
  • Ultrasound
  • Patient Care
    Patient Care Products
    • Catheterization Trainer (Male/Female)
    • Combat Carl
    • ECMO Trainer Professional MK2
    • Epidural-Spinal Injection
    • Lena Leg
    • ECMO Trainer Professional MK2
    • THORAXIS Thoracic Neuraxial Simulator
    • Puncture Pete – Hyper Realistic IV Training Arm, Light Skin Color
    • Obesity Simulation Suit, Male
    • Obesity Simulation Suit, Female
    • Obesity Simulation Suit, Unisex
HomeX-Ray CT, MRI Rat Phantom (Cylindrical) for X-Ray CT, MRI
Rat Phantom (Cylindrical) for X-Ray CT, MRI True Phantom Solutions
Click to enlarge

Rat Phantom (Cylindrical) for X-Ray CT, MRI

Rat Phantom (Cylindrical) can be fabricated as a simple cylinder or as an anatomically correct rat. Either of these phantoms is a powerful tool that can be used for testing and calibration-related work of various medical imaging devices.

PLEASE NOTE: WE CAN CUSTOMIZE THIS PRODUCT BASED ON YOUR REQUIREMENTS
 
Add to quote
This product is already in your quote request list.
Browse the list
SKU: RT-C01 Categories: All Products, X-Ray CT, MRI, Geometrical Tag: rat phantom
  • Description
  • Additional information
Description

Rat Phantom (Cylindrical)

Rat Phantom (Cylindrical) is designed to mimic complex rat anatomy in a form of a simple cylinder. It is a powerful tool that can be used for testing and calibration-related work of various medical imaging devices.

The cylindrical phantom has a 27mm diameter and 70mm height, which correspond to the dimensions of small animals (i.e. a laboratory rat/mouse.)

This small phantom is MRI, and CT compatible, and it can be customized in size and shape. The internal features can also be modified in terms of shape and properties to fit the needs of any particular bio-medical research project. 

In terms of MRI applications, the phantom tissues have realistic T2 relaxation time values, which makes this product the best fit for any T2-weighted MRI imaging methods. Very good results can also be achieved with proton-density imaging methods. The phantom can still be imaged with T1-weighted methods, but the T1 values are less realistic, and they are within the range of about 100 ms.

Anatomy
  • Soft Body Tissue – for better imaging results and optical transparency, we set this tissue to be transparent and to have no speckles.
  • Organs without Speckles – those are organs which are softer than the surrounding body tissue. They appear brighter on T2-weigthed MRI images.
  • Organs with Speckles – those are the organs with higher stiffness and density (i.e. muscles). They appear brighter on T2-weigthed MRI images.
  • Cartilage Tissue – very stiff and much more attenuative tissue than the organs and body tissue. It appears darker on T2-weigthed MRI images.
  • Soft Organs with Speckles –  those are the softest organs in the phantom. They appear the brightest in the phantom on T2-weigthed MRI images (i.e. kidneys, liver, etc.).

Coming Soon...

*/ Small variations in appearance may be present due to material characteristics and routine production tolerances. /*

Technical Properties:

Type of Tissue Sound Velocity [m/s] Density [g/cm³] Hardness [Shore 00] T2 [ms] Speckles Attenuation Measured at 2.25 MHz [dB/cm]
(#1) – Transparent 1400 ± 10 1.00 40 50 NO 1.5 ± 0.2
(#2) – Transparent 1400 ± 10 1.01 30 65 NO 1.2 ± 0.2
(#3) – Red 1400 ± 10 1.04 30 65 YES 1.2 ± 0.2
(#4) – Cartilage 1850 ± 10 1.06 85 20 N/A 30 ± 2
(#5) – Non-Transparent 1400 ± 10 1.00 20 75 YES 1.0 ± 0.2

View our technical properties of the tissue-mimicking material in the tables accessible through the button below.

View Tables
Included in Order
  • Rat (Cylindrical) Phantom

  • User Manual/Assembly Instructions

  • 2-Year Warranty & Unlimited Customer Service

  • Hard Carry Case

Size & Weight

Phantom:

  • Size: 1 x 1 x 3 Inches
  • Weight: 1 Lb (approx.)

Shipment:

  • Size: 10 x 8 x 6 Inches
  • Weight: 3 Lbs (approx.)
Materials Used
  • Soft tissues and organs: composition of urethane-based soft resin

  • Synthetic bones: ceramic-reinforced urethane-based composite material

FAQ
  • Please refer to our FAQ page.
Additional information
Rat Models

Rat (Anatomical), Rat (Cylindrical), Rat (Sectional)

Model

X-Ray CT, US, X-Ray CT, MRI, X-Ray CT

Related products

LogoAdult Head (Modular) for X-Ray CT, US, MRI
Adult Head (Openable) for X-Ray CT, US, MRI - True Phantom Solutions
Close

Adult Head (Modular) for X-Ray CT, US, MRI

LogoNewborn Head (Simple) for X-Ray CT, US, MRI
Close

Newborn Head (Simple) for X-Ray CT, US, MRI

LogoAdult Brain (Basic) for X-Ray CT, US, MRI True Phantom Solutions
Close

Adult Brain (Basic) for X-Ray CT, US, MRI

LogoNewborn Torso (Transparent) for X-Ray CT, US True Phantom Solutions
Add to quote
This product is already in your quote request list.
Browse the list
Close

Newborn Torso (Transparent) for X-Ray CT, US

Product Warranty

TPS offers a 2-year warranty on all products. We guarantee high-quality results and satisfied customers.

Custom Phantoms​

Customization is offered with almost any phantom. We can change the product to meet your requirements.

Ship Worldwide

TPS offers shipping to everywhere in the world! With help from FedEx, UPS, etc.

Patented

Our patented bone-mimicking material ensures the product provides customers with high quality imaging results.

true phantom solutions logo

True Phantom Solutions (TPS) specializes in the design and manufacturing of synthetic medical training models known as phantoms.

Facebook Twitter Instagram Youtube
Company
  • About Us
  • Privacy Policy
  • Publications
  • Blog
  • Radiographs
ontario_made_logo
Documents
  • Product Catalog
  • Warranty Policy
  • Quality Policy
  • Order Cancellation And Return Policy
  • Terms & Conditions
  • FAQ
Customer Service
  • Contact Us
  • Careers
  • Request a Quote
  • Chat Support
  • Complaint Form
Categories
  • X-Ray CT, US, MRI
  • X-Ray CT, US
  • X-Ray CT, MRI
  • X-Ray CT
  • Ultrasound
  • Patient Care

True Phantom Solutions — 2026 All Right Reserved

  • Sitemap
  • Home
  • About
  • Radiographs
  • Publications
  • Contact
  • Products
    • X-Ray, CT, US, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, US
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Ultrasound
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Patient Care
  • News
  • Careers
Shopping cart
close
  • Home
  • About
  • Radiographs
  • Publications
  • Contact
  • Products
    • X-Ray, CT, US, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, US
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Ultrasound
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Patient Care
  • News
  • Careers