• [email protected]
  • (519) 250-2058
  • 2090 Fasan Dr, Oldcastle, ON N0R 1L0

Follow Us

Facebook Instagram Youtube X-twitter Linkedin
  • Home
  • About
  • Radiographs
    • X-Ray Scans
    • Ultrasound Scans
    • CT Scans
    • MRI Scans
  • Publications & News
    • Publications
    • News
  • Contact
  • Home
  • About
  • Radiographs
    • X-Ray Scans
    • Ultrasound Scans
    • CT Scans
    • MRI Scans
  • Publications & News
    • Publications
    • News
  • Contact
Quotes
  • All Products
  • X-Ray CT, US, MRI
    Adults
    • Head (Dynamic, Advanced)
    • Head (Standard)
    • Female Heart
    • Heart
    • Brain (Complex)
    • Skull
    • View All
    Pediatric
    • Newborn Skull
    • Newborn Head (Dynamic)
    Geometrical
    • Cylindrical Head
    • Cylindrical Skull
    • Planar Skull Bone Phantoms
    • Doppler Phantom
  • X-Ray CT, US
    Adults
    • Torso (Skin)
    • Full Body (with Muscles)
    • Full Body
    • Torso (Dynamic)
    • Torso (Cardiac/FAST)
    • Knee (Extended)
    • Sectional Abdomen
    • Pelvis with Organs
    • Female Torso
    Pediatric
    • Pediatric Full Body
    • Newborn Torso
    • Newborn Head (Complex)
    • Newborn Torso (Advanced)
    • Newborn Head (Simple)
    • Newborn Arm
    Veterinary
    • Dog Phantom
    • Rat Phantom (Anatomical)
    Geometrical
    • Rat Phantom (Cylindrical)
  • X-Ray CT, MRI
    Adults
    • Full Body (with Muscles)
    • Torso
    • Female Torso
    • Torso (Dynamic)
    • Full Body
    • Torso (Cardiac)
    • Pelvis with Organs
    Pediatric
    • Full Body
    • Hand
    • Newborn Torso (Advanced
    Veterinary
    • Rat Phantom (Anatomical)
    • Dog Phantom
    Geometrical
    • Rat Phantom (Cylindrical)
  • X-Ray CT
    Adults
    • Full Body
    • Adult Spine
    Veterinary
    • Sectional Rat
    • Sectional Mouse
  • Ultrasound
  • Patient Care
    Patient Care Products
    • Catheterization Trainer (Male/Female)
    • Combat Carl
    • ECMO Trainer Professional MK2
    • Epidural-Spinal Injection
    • Lena Leg
    • NEMO Advanced Neonatal Emergency Manikin
    • NEMO Complete Neonatal
    • ECMO Trainer Professional MK2
    • NEMO Essential Infant Manikin
    • NEMO Premium High End Neonatal Simulation Manikin
    • NEMO Ultimate High End Neonatal Simulation Manikin
    • Obesity Simulation Suit,
      Female
    • Obesity Simulation Suit,
      Male
    • Obesity Simulation Suit,
      Unisex
    • Puncture Pete – Hyper Realistic IV Training Arm, Light Skin Color
    • THORAXIS Thoracic Neuraxial Simulator
HomeX-Ray CT, US, MRI Adult Arm for X-Ray CT, US, MRI
Adult Arm for X-Ray CT, US, MRI
Click to enlarge

Adult Arm for X-Ray CT, US, MRI

The Adult Arm for X-Ray/CT, US, and MRI has a joint at the elbow for flexibility and motion. It connects the lower arm with the upper arm. These two parts can be disarticulated as per needs. Our patented bone mimicking material allows for realistic X-ray/CT, US, and MRI images. 

PLEASE NOTE: WE CAN CUSTOMIZE THIS PRODUCT BASED ON YOUR REQUIREMENTS
  • Arm (Default)
  • Arm (Complex)
  • Arm (With Elbow)
Clear
Add to quote
This product is already in your quote request list.
Browse the list
SKU: AR-A01 Categories: Adults, All Products, X-Ray CT, US, MRI Tags: arm phantom, forearm phantom, radiography phantom
  • Description
  • Additional information
Description

Adult Arm (Deafult)

Adult Arm for X-Ray/CT, US, and MRI are a part of our Adult Full Body Phantom for X-Ray CT and MRI training [FB-A01] that can be purchased independently. 

This X-Ray CT and MRI Arm Phantom can be used to take X-Ray images of the entire arm. The model includes synthetic bones cast individually from our realistic patented bone-mimicking material. The X-Ray Arm Model is perfect for radiology schools for training and learning different settings of X-Ray without the danger of exposing an actual patient to harmful radiation. 

In terms of MRI applications, the phantom tissues have realistic T2 relaxation time values, which makes this product to be the best fit for any T2-weighted MRI imaging methods. Very good results can also be achieved with proton-density imaging methods. The phantom can still be imaged with T1-weighted methods, but the T1 values are less realistic, and they are within the range of about 100ms.

The bones are embedded in a realistic tissue-mimicking material that can be either transparent or opaque. The X-Ray Models may differ in size and shape. Due to production technology, there may be discoloring inside the phantom. This is related to the production method, and it does not affect the performance of the phantom.

Anatomy
  • Arm (Humerus)
  • Elbow Joints
  • Forearm (Radius, Ulna)
  • Hand (Wrist with Fingers)

Note: By default, the phantom comes in a translucent amber appearance. The skin feature can be included upon request.

*/ Small variations in appearance may be present due to material characteristics and routine production tolerances. /*

Note: By default, the phantom comes in a translucent amber appearance. The skin feature can be included upon request.

*/ These X-Ray scans were obtained from our product, Adult Full Body (with Muscles) for X-Ray CT, MRI SKU: FB-A02. This phantom will only include the arm portion. If you have any questions related to these, please write us at [email protected] /*

*/ This CT scan was obtained from our product, Adult Full Body (with Muscles) for X-Ray CT, MRI SKU: FB-A02. The image is only for quality reference, this phantom only includes a single arm. If you have any questions related to these, please write us at [email protected] /*

Technical Properties:

Type of TissuesSound Velocity [m/s]Density
[g/cm³]
Hardness
[Shore 00]
T2
[ms]
Hounsfield ValueAttenuation Measured
at 2.25 MHz [dB/cm]
Cortical Bone3000 ± 302.31N/AN/A13006.4 ± 0.3
Trabecular Bone2800 ± 502.03N/AN/A130021 ± 2
Body Tissue1410 ± 101.026050 ms251.7 ± 0.2
Thermal Properties of Bone-Mimicking Material
Thermal ConductivityVolumetric Specific Heat CapacityThermal DiffusivityThermal ResistivitySpecific HeatSpeed of Sound
0.776 W/ m K1.040 MJ/ m^3 K0.746 mm^2/ s1.289 m K/ W0.978 J/ g Deg Celsius3070 m/s
HU Values of the Tissue-Mimicking Materials
S.No.Tissue TypeHU Value (average)
1Trabecular Bone800
2Cortical Bone1300
3Soft Tissue-25

View our technical properties, thermal properties of bone-mimicking tissue, and HU values of the tissue-mimicking material in the tables accessible through the button below.

View Tables
Included in Order
  • Adult Arm Phantom

  • User Manual/Assembly Instructions

  • 2-Year Warranty & Unlimited Customer Service

Size & Weight

Phantom:

  • Size: 7 x 7 x 24 Inches,
  • Weight: 8 Lbs (approx.).

Shipment:

  • Size: 16 x 12 x 7 Inches,
  • Weight: 13 Lbs (approx.)
Materials Used:
  • Soft tissue and organs: Composition of urethane-based soft resin

  • Synthetic bones: Patented ceramic-reinforced epoxy-based composite material

FAQ
  • Please refer to our FAQ page.
Additional information
Arm Model

Arm (Default), Arm (Complex), Arm (With Elbow)

Related products

LogoAdult Skull for X-Ray CT, US, MRI
Close

Adult Skull for X-Ray CT, US, MRI

LogoNewborn Torso (Advanced) for X-Ray CT, US
Add to quote
This product is already in your quote request list.
Browse the list
Close

Newborn Torso (Advanced) for X-Ray CT, US

LogoAdult Head (Dynamic) for X-Ray CT, US, MRI
Close

Adult Head (Dynamic) for X-Ray CT, US, MRI

LogoNewborn Torso (Transparent) for X-Ray CT, US
Add to quote
This product is already in your quote request list.
Browse the list
Close

Newborn Torso (Transparent) for X-Ray CT, US

Product Warranty

TPS offers a 2-year warranty on all products. We guarantee high-quality results and satisfied customers.

Custom Phantoms​

Customization is offered with almost any phantom. We can change the product to meet your requirements.

Ship Worldwide

TPS offers shipping to everywhere in the world! With help from FedEx, UPS, etc.

Patented

Our patented bone-mimicking material ensures the product provides customers with high quality imaging results.

True Phantom Solutions (TPS) specializes in the design and manufacturing of synthetic medical training models known as phantoms.

Facebook Twitter Instagram Youtube
Company
  • About Us
  • Privacy Policy
  • Publications
  • Blog
  • Radiographs
ontario_made_logo
Documents
  • Product Catalog
  • Warranty Policy
  • Quality Policy
  • Return Policy
  • Terms & Conditions
  • FAQ
Customer Service
  • Contact Us
  • Careers
  • Request a Quote
  • Chat Support
  • Complaint Form
Categories
  • X-Ray CT, US, MRI
  • X-Ray CT, US
  • X-Ray CT, MRI
  • X-Ray CT
  • Ultrasound
  • Patient Care

True Phantom Solutions — 2026 All Right Reserved

  • Sitemap
  • Home
  • About
  • Radiographs
  • Publications
  • Contact
  • Products
    • X-Ray, CT, US, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, US
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Ultrasound
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Patient Care
  • News
  • Careers
Shopping cart
close
  • Home
  • About
  • Radiographs
  • Publications
  • Contact
  • Products
    • X-Ray, CT, US, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, US
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Ultrasound
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Patient Care
  • News
  • Careers