Adult Arm (Fractured)
The Adult Arm (Fractured) Phantom is a life-size, anatomically realistic training and imaging model designed to replicate the anatomy of the human upper extremity with simulated bone fractures. Compatible with X-ray, CT, MRI, and ultrasound imaging modalities, this versatile phantom is ideal for medical imaging education, clinical training, research, device evaluation, and protocol development.
The phantom enables users to assess and optimize diagnostic imaging procedures across a wide range of positioning techniques, imaging orientations, and scanning parameters. Its realistic anatomical structure and fracture representation provide valuable opportunities for practicing image acquisition, evaluating image quality, and developing advanced imaging workflows.
For MRI applications, the phantom tissues exhibit realistic T2 relaxation time values, making it particularly well suited for T2-weighted imaging techniques. Excellent image quality can also be achieved using proton-density-weighted MRI sequences. While the phantom remains compatible with T1-weighted imaging methods, the T1 relaxation times are less physiologically representative, with values typically around 100 ms.
To accommodate specific educational and research requirements, the phantom can also be customized with a variety of additional pathologies and anatomical modifications upon request, making it suitable for specialized training applications, targeted device testing, and protocol validation studies.
Forearm (Radius, Ulna)
Wrist with Fingers
Soft tissue-mimicking material
- Bone Fractures (2)
– Distal Radius Fracture
– Spiral Ulna Fracture
Technical Properties:
| Type of Tissue | Sound Velocity [m/s] | Density [g/cm³] | Hardness [Shore 00] | T2 [ms] | Hounsfield Value | Attenuation Measured at 2.25 MHz [dB/cm] |
| Cortical Bone | 3000 ± 30 | 2.31 | N/A | N/A | 1300 | 6.4 ± 0.3 |
| Trabecular Bone | 2800 ± 50 | 2.03 | N/A | N/A | 1300 | 21 ± 2 |
| Body Tissue | 1410 ± 10 | 1.02 | 60 | 50 ms | 25 | 1.7 ± 0.2 |
| Muscle Tissue | 1400 ± 10 | 1.01 | 35 | 60 | N/A | 1.3 ± 0.2 |
| Thermal Properties of Bone-Mimicking Material | |||||
| Thermal Conductivity | Volumetric Specific Heat Capacity | Thermal Diffusivity | Thermal Resistivity | Specific Heat | Speed of Sound |
| 0.776 W/ m K | 1.040 MJ/ m^3 K | 0.746 mm^2/ s | 1.289 m K/ W | 0.978 J/ g Deg Celsius | 3070 m/s |
| HU Values of the Tissue-Mimicking Materials | ||
| S.No. | Tissue Type | HU Value (average) |
| 1 | Trabecular Bone | 800 |
| 2 | Cortical Bone | 1300 |
View our technical properties, thermal properties of bone-mimicking tissue, and HU values of the tissue-mimicking material in the tables accessible through the button below.
Adult Arm (Fractured) Phantom
User Manual/Assembly Instructions
2-Year Warranty & Unlimited Customer Service
Phantom:
- Size: 7 x 7 x 24 Inches
- Weight: 8 Lbs (approx.).
Shipment:
- Size: 16 x 12 x 7 Inches
- Weight: 13 Lbs (approx.)
- Soft tissue and organs: Composition of urethane-based soft resin
- Synthetic bones: Patented ceramic-reinforced epoxy-based composite material