• [email protected]
  • (519) 250-2058
  • 2090 Fasan Dr, Oldcastle, ON N0R 1L0

Follow Us

Facebook Instagram Youtube X-twitter Linkedin
Official logo of True Phantom Solutions
  • Home
  • About
  • Radiographs
    • X-Ray Scans
    • Ultrasound Scans
    • CT Scans
    • MRI Scans
  • Publications & News
    • Publications
    • News
  • Contact
  • Home
  • About
  • Radiographs
    • X-Ray Scans
    • Ultrasound Scans
    • CT Scans
    • MRI Scans
  • Publications & News
    • Publications
    • News
  • Contact
Quotes
Official logo of True Phantom Solutions
  • All Products
  • X-Ray CT, US, MRI
    Adults
    • Head (Dynamic, Advanced)
    • Head (Standard)
    • Female Heart
    • Heart
    • Brain (Complex)
    • Skull
    • View All
    Pediatric
    • Newborn Skull
    • Newborn Head (Dynamic)
    Geometrical
    • Cylindrical Head
    • Cylindrical Skull
    • Planar Skull Bone Phantoms
    • Doppler Phantom
  • X-Ray CT, US
    Adults
    • Torso (Skin)
    • Full Body (with Muscles)
    • Full Body
    • Torso (Dynamic)
    • Torso (Cardiac/FAST)
    • Knee (Extended)
    • Sectional Abdomen
    • Pelvis with Organs
    • Female Torso
    Pediatric
    • Pediatric Full Body
    • Newborn Torso
    • Newborn Head (Complex)
    • Newborn Torso (Advanced)
    • Newborn Head (Simple)
    • Newborn Arm
    Veterinary
    • Dog Phantom
    • Rat Phantom (Anatomical)
    Geometrical
    • Rat Phantom (Cylindrical)
  • X-Ray CT, MRI
    Adults
    • Full Body (with Muscles)
    • Torso
    • Female Torso
    • Torso (Dynamic)
    • Full Body
    • Torso (Cardiac)
    • Pelvis with Organs
    Pediatric
    • Full Body
    • Hand
    • Newborn Torso (Advanced
    Veterinary
    • Rat Phantom (Anatomical)
    • Dog Phantom
    Geometrical
    • Rat Phantom (Cylindrical)
  • X-Ray CT
    Adults
    • Full Body
    • Adult Spine
    Veterinary
    • Sectional Rat
    • Sectional Mouse
  • Ultrasound
  • Patient Care
    Patient Care Products
    • Catheterization Trainer (Male/Female)
    • Combat Carl
    • ECMO Trainer Professional MK2
    • Epidural-Spinal Injection
    • Lena Leg
    • NEMO Advanced Neonatal Emergency Manikin
    • NEMO Complete Neonatal
    • ECMO Trainer Professional MK2
    • NEMO Essential Infant Manikin
    • NEMO Premium High End Neonatal Simulation Manikin
    • NEMO Ultimate High End Neonatal Simulation Manikin
    • Obesity Simulation Suit,
      Female
    • Obesity Simulation Suit,
      Male
    • Obesity Simulation Suit,
      Unisex
    • Puncture Pete – Hyper Realistic IV Training Arm, Light Skin Color
    • THORAXIS Thoracic Neuraxial Simulator
HomeX-Ray CT, US, MRI Adult Arm (Fractured) for X-Ray CT, US, MRI
Adult Arm (Fractured) for X-Ray CT, US,MRI
Life-size adult arm fractured phantom for radiology, CT, and ultrasound device testing true phantom solutions
True Phantom Solutions adult arm fractured phantom showing 3D-printed bones and soft tissue-mimicking material for medical imaging training
true phantom solutions fractured arm phantom with a distal radius fracture and spiral ulna fracture for X-ray, CT, ultrasound, and MRI imaging
Click to enlarge

Adult Arm (Fractured) for X-Ray CT, US, MRI

The Adult Arm (Fractured) Phantom is a life-size, anatomically realistic model featuring simulated bone fractures. Compatible with X-ray, CT, MRI, and ultrasound imaging, it is ideal for medical imaging education, research, device testing, and protocol development. The phantom enables the evaluation of diagnostic procedures across a variety of positioning techniques and imaging orientations.

PLEASE NOTE: WE CAN CUSTOMIZE THIS PRODUCT BASED ON YOUR REQUIREMENTS
Add to quote
This product is already in your quote request list.
Browse the list
SKU: AR-A04 Categories: All Products, Adults, X-Ray CT, US, MRI Tags: arm phantom, radiography phantom, ultrasound phantom
  • Description
  • Additional information
Description

Adult Arm (Fractured)

The Adult Arm (Fractured) Phantom is a life-size, anatomically realistic training and imaging model designed to replicate the anatomy of the human upper extremity with simulated bone fractures. Compatible with X-ray, CT, MRI, and ultrasound imaging modalities, this versatile phantom is ideal for medical imaging education, clinical training, research, device evaluation, and protocol development.

The phantom enables users to assess and optimize diagnostic imaging procedures across a wide range of positioning techniques, imaging orientations, and scanning parameters. Its realistic anatomical structure and fracture representation provide valuable opportunities for practicing image acquisition, evaluating image quality, and developing advanced imaging workflows.

For MRI applications, the phantom tissues exhibit realistic T2 relaxation time values, making it particularly well suited for T2-weighted imaging techniques. Excellent image quality can also be achieved using proton-density-weighted MRI sequences. While the phantom remains compatible with T1-weighted imaging methods, the T1 relaxation times are less physiologically representative, with values typically around 100 ms.

To accommodate specific educational and research requirements, the phantom can also be customized with a variety of additional pathologies and anatomical modifications upon request, making it suitable for specialized training applications, targeted device testing, and protocol validation studies.

Anatomy
  • Forearm (Radius, Ulna)

  • Wrist with Fingers

  • Soft tissue-mimicking material

  • Bone Fractures (2)
    – Distal Radius Fracture
    – Spiral Ulna Fracture

Note: By default, the phantom comes in a translucent amber appearance. A skin feature can be included upon request.

*/ Small variations in appearance may be present due to material characteristics and routine production tolerances. /*

Technical Properties:

Type of TissueSound Velocity [m/s]Density
[g/cm³]
Hardness
[Shore 00]
T2
[ms]
Hounsfield ValueAttenuation Measured
at 2.25 MHz [dB/cm]
Cortical Bone3000 ± 302.31N/AN/A13006.4 ± 0.3
Trabecular Bone2800 ± 502.03N/AN/A130021 ± 2
Body Tissue1410 ± 101.026050 ms251.7 ± 0.2
Muscle Tissue1400 ± 101.013560N/A1.3 ± 0.2
Thermal Properties of Bone-Mimicking Material
Thermal ConductivityVolumetric Specific Heat CapacityThermal DiffusivityThermal ResistivitySpecific HeatSpeed of Sound
0.776 W/ m K1.040 MJ/ m^3 K0.746 mm^2/ s1.289 m K/ W0.978 J/ g Deg Celsius3070 m/s
HU Values of the Tissue-Mimicking Materials
S.No.Tissue TypeHU Value (average)
1Trabecular Bone800
2Cortical Bone1300

View our technical properties, thermal properties of bone-mimicking tissue, and HU values of the tissue-mimicking material in the tables accessible through the button below.

View Tables
Included in Order
  • Adult Arm (Fractured) Phantom

  • User Manual/Assembly Instructions

  • 2-Year Warranty & Unlimited Customer Service

Size & Weight

Phantom:

  • Size: 7 x 7 x 24 Inches
  • Weight: 8 Lbs (approx.).

Shipment:

  • Size: 16 x 12 x 7 Inches
  • Weight: 13 Lbs (approx.)
Materials Used:
  • Soft tissue and organs: Composition of urethane-based soft resin
  • Synthetic bones: Patented ceramic-reinforced epoxy-based composite material
FAQ
  • Please refer to our FAQ page.
Additional information
Arm Model

Arm (Default), Arm (Complex), Arm (With Elbow)

Related products

LogoAdult Arm for X-Ray CT, US, MRI
Close

Adult Arm for X-Ray CT, US, MRI

LogoAdult Brain (Basic) for X-Ray CT, US, MRI
Close

Adult Brain (Basic) for X-Ray CT, US, MRI

LogoAdult Skull for X-Ray CT, US, MRI
Close

Adult Skull for X-Ray CT, US, MRI

LogoNewborn Skull for X-Ray CT, US, MRI
Add to quote
This product is already in your quote request list.
Browse the list
Close

Newborn Skull for X-Ray CT, US, MRI

Product Warranty

TPS offers a 2-year warranty on all products. We guarantee high-quality results and satisfied customers.

Custom Phantoms​

Customization is offered with almost any phantom. We can change the product to meet your requirements.

Ship Worldwide

TPS offers shipping to everywhere in the world! With help from FedEx, UPS, etc.

Patented

Our patented bone-mimicking material ensures the product provides customers with high quality imaging results.

True Phantom Solutions (TPS) specializes in the design and manufacturing of synthetic medical training models known as phantoms.

Facebook Twitter Instagram Youtube
Company
  • About Us
  • Privacy Policy
  • Publications
  • Blog
  • Radiographs
ontario_made_logo
Documents
  • Product Catalog
  • Warranty Policy
  • Quality Policy
  • Order Cancellation And Return Policy
  • Terms & Conditions
  • FAQ
Customer Service
  • Contact Us
  • Careers
  • Request a Quote
  • Chat Support
  • Complaint Form
Categories
  • X-Ray CT, US, MRI
  • X-Ray CT, US
  • X-Ray CT, MRI
  • X-Ray CT
  • Ultrasound
  • Patient Care

True Phantom Solutions — 2026 All Right Reserved

  • Sitemap
  • Home
  • About
  • Radiographs
  • Publications
  • Contact
  • Products
    • X-Ray, CT, US, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, US
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Ultrasound
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Patient Care
  • News
  • Careers
Shopping cart
close
  • Home
  • About
  • Radiographs
  • Publications
  • Contact
  • Products
    • X-Ray, CT, US, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, US
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT, MRI
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • X-Ray, CT
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Ultrasound
      • Adults
      • Pediatric
      • Veterinary
      • Geometrical
    • Patient Care
  • News
  • Careers